qiao@hvtest.cc15871365102
  • UHV-2671A Digital Insulation Resistance Tester

    UHV-2671A сандық оқшаулау кедергісін тексеру құралы осы жабдықтың қалыпты жұмысын қамтамасыз ету үшін электр жабдығының немесе электр кабелінің жерге оқшаулау кедергісін тексеру үшін қолданылады. Жабдықтың үлкен шығыс қуаты, жоғары қысқа тұйықталу ток мәні және шығыс кернеуінің бірнеше деңгейлері бар

    Product Details of UHV-2671A Digital Insulation Resistance Tester


    Өнімге кіріспе

    The UHV-2671A Digital Megohmmeter, manufactured by Wuhan UHV, is designed using medium- and large-scale integrated circuits.Wuhan UHV Power Technology Co.,Ltd., is a professional manufacturer and supplier of high-voltage power testing equipment in China.

    This meter features high output power, a high short-circuit current value, and multiple output voltage levels.The operating principle is as follows: the DC high voltage generated by DC/DC conversion from the internal battery serves as the power source. This voltage is applied from the E terminal to the L terminal through the device under test, generating a current flow from E to L. After I/V conversion and division, the measured insulation resistance value is directly displayed on the LCD screen.

    1 (6)1 (7)

    Өнім сипаттамалары

    1. Auto Discharge Function: Ensures safer operation by automatically discharging residual voltage.

    2. LCD Backlight: Provides clear visibility in low-light conditions.

    3. Live Wire Warning: Features audible indication to alert users when a live wire is detected.

    4. Auto Power-Off: Automatically powers off after 10 minutes of inactivity to conserve battery life.

    5. Low Battery Indication: Alerts the user when the battery level is low, ensuring timely replacement or recharging.


    Техникалық параметрлер

    Номиналды кернеу100В250В500В1000В2500В
    Өлшеу диапазоны

    0.0-10MΩ

    10-100MΩ

    100-200MΩ

    0.0-10MΩ

    10-100MΩ

    100-500MΩ

    0.0-99.9MΩ

    100-999MΩ

    0.0-99.9MΩ

    100-999MΩ

    1.00-19.9GΩ

    0.0-99.9MΩ

    100-999MΩ

    1.00-9.99GΩ

    10.0-49.9GΩ

    Ашық контур

    Вольтаж

    Тұрақты ток 100В+10%Тұрақты ток 250В+10%Тұрақты ток 500В +20%Тұрақты ток 1000В+20%Тұрақты ток 2500В+20%

    Стандартты өлшеу

    ток

    0.5MΩ When the load

    0,2мА-0,25мА

    0.5MΩ When the load

    0,5мА-0,55мА

    0.5MΩ When the load

    1мА-1,1мА

    1.0MΩ When the load

    1мА-1,1мА

    2.5MΩ When the load

    1мА-1,1мА

    Қысқа тұйықталушамамен 1,3 мА
    дәлдік±5%rdg±5dgt

    Кернеуді өлшеу


    Айнымалы ток Айналыңыз
    Ауқым30-600В (50/60Гц)
    Ажыратымдылық1V
    Дәлдік±2%rdg±3dgt

    Техникалық сипаттама

    ПараметрИндекс
    СКД дисплейЕң көп саны 999
    Артық диапазон көрсеткіші

    OL:appears on insulation resistance

    LO:appears on voltage

    Автоматты диапазон

    Диапазонды жоғарғы диапазонға ауыстыру: 1000 санау

    Ауқымның төменгі диапазонға ауысуы: 95 санау (тек оқшаулауда)

    Іріктеу жылдамдығы0,5-10 рет/сек
    Операция≤2000m(indoor use)
    Жұмыс ортасыThe temperature:0°C-40°C humidity:≤85%
    Сақтау ортасыThe temperature:-20°C-60°C humidity:≤90%
    Шамадан тыс жүктемеден қорғау

    Insulation resistance range: AC 1200V/10 seconds

    Voltage range: AC 720V/10 seconds

    Кернеуге төзімдіAC 8320V(50/60Hz)/5 seconds (between circuit and periphery)
    Оқшаулау кедергісі>1000MQ/DC 1000V (тізбек пен периферия арасында)
    нәр берушіDC9V(6*л,5В AA батареясы)
    Батареяшамамен. 800мА(макс)
    Батареяның қызмет ету мерзімішамамен. 15 сағат
    Өлшем125,4 x 174,6 x 69 мм
    Салмағы547,44 г (батареясыз және сынақ сымсыз)

    Application Scenarios

    Power cable insulation testing
    Used to test the insulation performance between cable cores, and between cores and ground. Commonly used in cable installation acceptance, maintenance, and fault diagnosis.

    Motor / generator insulation testing
    Used to test the insulation condition of motor and generator windings, determining whether there are issues such as moisture, aging, or degraded insulation performance.

    Transformer insulation testing
    Used to test the insulation performance between transformer windings and ground, and between windings. It is an important test item in transformer maintenance and preventive maintenance.

    Switchgear / distribution cabinet insulation testing
    Used to check the insulation condition of electrical circuits inside switchgear and distribution cabinets, suitable for installation commissioning, pre-energization inspection, and routine maintenance.

    Substation electrical equipment insulation testing
    Used for insulation condition checking of various electrical equipment in substations, helping to identify potential leakage and insulation aging issues.

    Preventive maintenance of industrial electrical equipment
    Used for periodic insulation testing of motors, cables, distribution equipment, and other electrical equipment in factories, reducing the risk of equipment failure and unplanned downtime.

    Building electrical line installation acceptance
    Used for line insulation testing before completion and energization of building electrical projects, confirming that electrical lines meet safety operation requirements.

    Electrical equipment fault diagnosis and repair
    Used for insulation testing when equipment experiences leakage, tripping, or abnormal operation, assisting in determining whether equipment has insulation damage, moisture, or aging issues.

    Photovoltaic / new energy electrical system insulation testing
    Can be used for insulation testing of cables and electrical circuits in some photovoltaic, energy storage, and other new energy systems, suitable for installation commissioning and operation and maintenance inspection.


    Frequently Asked Questions

    Q: What is this insulation resistance tester mainly used for?

    A: It is mainly used for testing the insulation performance of electrical equipment and cables, determining whether there are issues such as insulation aging, moisture, or leakage.

    Q: What are the common causes of abnormal insulation resistance test results?

    A: Common causes include equipment moisture, insulation aging, damaged insulation materials, surface contamination, broken wiring, or abnormal connections. The specific cause requires further inspection.

    Q: What problem is this device best suited to solve?

    A: Its core purpose is to help users determine the insulation condition of electrical equipment and cables. It is used for installation acceptance, routine maintenance, fault diagnosis, and post-repair safety inspections.


    Maintenance

    1.Do not store or use the unit in following circumstance:
    a. Splashes of water or high levels of dust.
    b. Air of high salt or sulphur content.
    c. Air mixed with other gases or chemical contents.
    d. High temperature or humidity (above 60°C, 90%RH,) or direct sunlight.
    2. Do not disassemble the unit or attempt any internal a Iterations.
    3. Never use alcohol or diluents to clean the housing for doing that will especially erode the LCD surface; just clean the unit lightly as needed with little cleanwater.