UHV жиілігін түрлендіру айнымалы ток сериясының резонанстық сынақ жүйесі
Өнімге кіріспе
The UHV series resonant system is suitable for large-capacity, high-voltage capacitance testing and preventive tests, featuring multiple protection functions such as over-voltage, over-current, zero-start, and system detuning (flashover). Adopting DSP platform technology, the entire unit is lightweight and convenient for on-site use.

Өнім параметрлері
Техникалық параметр
| Номиналды шығыс кернеуі | 0~1000kV and below |
| шығыс жиілігі | 30~300Hz |
| Resonance voltage waveform | Pure sine wave, waveform distortion rate≤1.0% |
| Жұмыс уақыты | Full power continuous working time of 60min |
| Сапа факторы | 30~90 |
| Жиілікті реттеу сезімталдығы | 0,1 Гц |
| Тұрақсыздық | <0.05% |
| Жұмыс істейтін қуат көзі | Бірфазалы 220В немесе үш фазалы 380В±10% |
| Қуат жиілігі 50Гц±5% |
Serial product configuration(Application range (10kV ~ 500kV voltage grade substation electrical equipment ac withstand voltage equipment, frequency 30 ~ 300Hz))
| Product model name | Айнымалы жиілік көзі | Резонанстық реактор | Қоздырғыш түрлендіру | Кернеу бөлгіш | Қолдану аясы |
| UHV-50/50 | 4кВт | 25kV/1A two(dry) | 4kVA(dry) | 50кВ | 1000kVA and below 10kV power transformer. 10kV switch , bus, PT, CT, etc. 10 kv (300mm2) cable 1.0 km or less |
| UHV-108/108 | 6кВт | 27kV/1A four(dry) | 6kVA(dry) | 110кВ | 31500kVA and below 35kV power transformer. 35kV switch , bus, PT, CT, etc. 10 kv (300 mm2)cable≤2km.35kV (300mm2)cable≤0.5km |
| UHV-200/200 | 10кВт | 50kV/1A four(dry) | 10kVA(dry) | 200кВ | 50000kVA and below 110kV power transformer.110kVGIS、PT、CT etc.(Preventive test).35kV(300mm2)cable≤1.0km.10kV (300mm2)cable≤2.0km |
| UHV-270/270 | 15кВт | 45kV/1A Six sets of(dry) | 15kVA(dry) | 300кВ | 50000kVA and below 110kV power transformer.110kVGIS、PT、CT etc..35kV(300mm2)cable≤1.2km.10kV (300mm2)cable≤3.0km |
| UHV-800/400 | 30кВт | 50kV/2A eight(dry); 100kV/2A four(oil-immersed) | 30kVA(dry); 30kVA(oil-immersed) | 400кВ | 80000kVA and below 220kV power transformer.50000kVA and below 110kV power transformer.110kV/220kVGIS、PT、CT etc..35kV(300mm2)cable≤2.0km.110kV (300mm2)cable≤0.7km |
| UHV-1600/800 | 60кВт | 200kV/2A four(oil-immersed) | 60kVA(dry) | 800кВ | 220kV power transformer of 80000kVA and below.50000kVA and below 110kV power transformer.500kVGIS、PT、CT etc..220kV switch 、GIS、PT、CT etc..110kV(400mm2)cable≤1.5km.220kV (400mm2)cable≤1.0km |
Негізгі артықшылықтары
1, Кешенді қауіпсіздік:Үлгіні де, құрылғыны да қорғау үшін пайдаланушы реттейтін қорғаныс шектерін қамтитын көп сатылы қорғаныспен (асқын кернеу, асқын ток, нөлдік іске қосу және жеделдетуді баптауды азайту) жабдықталған.
2, Икемділік пен тиімділікті арттыру:Әртүрлі далалық жағдайларға бейімделу және сынақ жылдамдығын оңтайландыру үшін үш жұмыс режимін (толық автоматты, қолмен және автоматты баптау/қолмен күшейту) ұсынады.
3, жоғары пайдалану ыңғайлылығы: The entire unit is designed to be lightweight and portable for easy field deployment. It supports off-site data storage and printing, with numbered records for quick retrieval and identification.
4, Болашаққа дайын дизайн:Модульдік DSP платформасы пайдаланушы қажеттіліктеріне сәйкес ыңғайлы функционалды жаңартулар мен теңшеуге мүмкіндік береді, сонымен қатар интуитивті адам-машина интерфейсін ұсынады.
![]() | ![]() |
The difference between power frequency withstand voltage test device and variable frequency series resonance test device.
Comparative dimension | Power frequency withstand voltage test device | Variable frequency series resonance test device |
Жұмыс принципі | Utilize a 50Hz power supply and directly boost the voltage through a regulator. | By adjusting the power frequency (usually 20-300Hz), the inductance in the circuit and the capacitance of the test sample are connected in series resonance to obtain high voltage. |
Equipment weight and volume | Heavy and cumbersome. Especially when the voltage level is high and the capacity is large, transformers and voltage regulators are bulky and inconvenient to transport on site. | light. By utilizing resonant boost, the required power capacity is only 1/5 to 1/10 of traditional methods, significantly reducing equipment weight. |
Applicable test samples | Suitable for low voltage level and small capacity equipment, such as small and medium-sized motors, switchgear, insulators, etc. | Specially designed for high-capacity and high-voltage capacitive test samples, such as long-distance power cables, large generators, GIS (gas insulated switchgear), and power transformers. |
Power capacity requirements | High. All the power required for the experiment is directly provided by the power supply, which imposes strict requirements on the on-site power supply. | Low. During circuit resonance, reactive power compensates for each other, and the power supply only needs to provide active power for system losses, with low capacity requirements. |
Security features | When the test sample breaks down, the short-circuit current is high, which may cause significant damage to the fault point. | Having comprehensive protection. After the breakdown of the test sample, the resonance condition is destroyed, and the voltage and short-circuit current will automatically and rapidly decrease, causing minimal damage to the test sample. |
Cost and Budget | Relatively inexpensive. The structure is simple, the technology is mature, and it is a low-cost solution for one-time investment. | Relatively high. Including variable frequency power supply, excitation transformer, adjustable reactor, etc., with many electronic components and more complex technology. |
Typical application of series resonance: covering high-voltage detection scenarios in multiple industries
The application of series resonance technology has penetrated into multiple fields such as power, new energy, and rail transit, becoming a "standard solution" for high-voltage equipment testing.
1. In the power system, the voltage withstand test of transformers, GIS composite equipment, high-voltage cables and other equipment in substations generally adopts the series resonance equipment of Wuhan ultra-high voltage. Taking the 110kV cable detection as an example, the equipment can output a resonant voltage of 126kV and continuously apply pressure for 15 minutes to accurately detect whether there are defects in the cable insulation. Due to low power consumption, only a small generator is needed for power supply, which is suitable for outdoor field operations.
2. In the new energy industry, high-voltage equipment such as inverters for photovoltaic power plants and box type substations for wind power need to undergo series resonance testing to verify their insulation performance before leaving the factory. The equipment of Wuhan ultra-high voltage can automatically match inductance according to the capacitance of the test sample, adapt to different specifications of equipment for testing, and meet the batch testing needs of new energy enterprises.
3. In the field of rail transit, the voltage withstand test of high-speed rail traction transformers and contact network equipment requires extremely high equipment stability. Its series resonant equipment, with strong anti-interference ability and stable voltage output, can accurately complete testing in complex electromagnetic environments along railways, ensuring the safety of train power supply systems.
FAQ about AC resonant test systems